The Hanningfield Scheme

1960 , Hanningfield (Essex)

No video

There’s no web video for this work.

Please do get in contact to discuss other ways you could view this work.

The building of the Hanningfield scheme to provide water for Southend-on-Sea and South Essex, and the official opening of the site.

A record of the construction of the Hanningfield reservoir between September 1952 and its opening in 1957: an animated plan explains the construction theory. In the second year of construction there is damming and pipe laying on the River Chelmer. Water treatment facilities are shown in some detail. By 1954, the site is almost complete; a steam powered grading machine is in use. The first water arrives at the reservoir in 1955: views of the pumping station at Langford, the treatment plant at Hanningford, laboratories, accelerators and the sludge lagoon. Filtration is explained. There are shots of the access roads, buildings and landscaped areas. The site is officially opened by the Minister of Housing and Local Government who plants a tree. The potential leisure uses of the site are pointed out. Shots of the South Essex and Southend Water Company building, and factory buildings with people leaving work. The narrator explains the expansion of Essex new towns and therefore increase in population requires an increase in the supply of water. Montage of shots show water and its many uses; rain and puddles, a kettle boiling, a baby being bathed, London’s Trafalgar Square fountain, a train emerging from a washing shed. In 1952, the South Essex and Southend Water Companies embarked on one of the largest post-war water schemes in the country; The Hanningfield Scheme. Officials on the steps at the Hanningfield water treatment plant following the opening of the reservoir in 1957. A map of Essex shows the districts covered by the South Essex Water Company, and the Southend Water Company, and the sources of their water supplies. The map then shows the site of the Hanningfield Reservoir, a joint project of these two companies, with its water source at Langford. An illustrated diagram of the reservoir shows a dam, water entry-point, outlet, valve-tower, pumping station, and treatment plant. September 1952; the foundations of the valve tower and work being carried out on site of the main dam, with bulldozers moving gravel. An animated diagram shows the valve pumping station. Excavating machines burrow down to the London clay bed on which the dam's core will be set. Clay is carried on conveyor belts to the "sausage machine", which minces the clay and mixes it with water to the correct consistency; the clay is carried to position by truck, and spread and beaten down into a solid mass by the workers’ boots. During the second year of construction, steel pipes are laid in trenches, this is to carry the water from Langford to Hanningfield. The River Chelmer is drained to allow for work to be carried out. The aforementioned pipeline is encased in concrete. Returning to the Hanningfield site where construction of the valve-tower and pumping plant is continuing, with aerial shots of the accelators. By 1954, the valve-tower is nearly complete and concrete slabbing has been laid on part of the embankment. A special machine mixes and lays concrete, and positions the slabs, and the embankment is swept clean with a tractor and attached leveler. Nine months later; the main aqueduct carries water down to the reservoir. There are aerial views of the reservoir followed by the installation of equipment inside the pumping station. By 1956, the reservoir is nearly completed. A road runs along the main embankment, and sludge pipes go to the lagoons. At the Langford pumping station, inside are the flow pumps. The treatment plant buildings at Hanningfield, then the detailed process of water softening is shown. Chemicals are added to the water in the accelators and bags of chemicals are unloaded from a lorry. Demonstration of how the sodium silicate and alumina flocculate reacts in water. A bulk delivery of limestone is unloaded at the site. The limestone passes through a crusher, and, together with soda ash is added to the water to reduce its hardness. Sludge collects in the accelators and is pumped off to the sludge lagoons. The clear, soft water, is drawn off at the accelator surface and is channeled to the contact tank. Here, activated carbon is added to remove residual taste or odour, and carbon dioxide gas to reduce alkalinity. Two pipes are shown, one corroded, the other uncorroded. Inside the filter house, cleaning the filter bed. Sampling and recording water content at each stage of purification is done in the laboratory. Water is finally sterilized with ammonia and chlorine. An overhead shot of the grounds where underneath is a storage tank. At the completed pumping station with various shots of buildings, and the reservoir, completely fenced around, with service roads, and staff housing. Henry Brooke, Minister of Housing at Local Government, plants a tree at a ceremony to mark the start of a landscape garden programme. There are views of the gardens, birds at the reservoir and fishing at the reservoir and shots of the surrounding countryside.

Featured Buildings

The pumping station, Langford; The water treatment plant, Hanningford

Featured Events

The opening of the Hanningfield Scheme, September 1957

Keywords

Civil engineering; Opening ceremonies; Reservoirs; Water treatment; Industrial Machinery; New Town Expansions; Reservoirs

  • Producer : Stanley Schofield

  • Sponsor : Hanningfied Water Joint Management Committee

Manifestations

The Hanningfield Scheme

  • Barcode
    INV391564
    Canonical Title
    Unknown
    Carrier Type
    DV digital
    Dimension
    Duration
    0:22:36
    Modification Date
    10/05/2011
    Parts
    Reference
    708528
  • Activities
    Barcode
    INV178888
    Canonical Identifier
    TB 23
    Canonical Title
    Unknown
    Carrier Type
    Umatic tape
    Dimension
    Identifier
    Modification Date
    21/07/2008
    Parts
    Reference
    672672
  • Activities
    Barcode
    INV286650
    Canonical Title
    Unknown
    Carrier Type
    master digital
    Colour Type
    colour
    Dimension
    Duration
    0:22:36
    Has Sound
    Y
    Modification Date
    22/05/2008
    Parts
    Reference
    670828
    Sound
    sound
  • Activities
    Barcode
    INV167923
    Canonical Identifier
    TB 1627
    Canonical Title
    Unknown
    Carrier Type
    Digibeta tape
    Dimension
    Identifier
    Modification Date
    22/05/2008
    Parts
    Reference
    670827
  • Activities
    Barcode
    INV274392
    Canonical Identifier
    S 1323
    Canonical Title
    Unknown
    Carrier Type
    DVD disk
    Dimension
    Identifier
    Modification Date
    10/04/2008
    Parts
    Reference
    669536
  • Activities
    Barcode
    INV??4589
    Canonical Identifier
    1996/71
    Canonical Title
    Unknown
    Identifier
    Modification Date
    25/06/2021
    Parts
    Reference
    566672
  • Activities
    Barcode
    INV??4588
    Canonical Identifier
    1996/71
    Canonical Title
    Unknown
    Identifier
    Modification Date
    25/06/2021
    Parts
    Reference
    566671
  • Activities
    Barcode
    INV??4587
    Canonical Identifier
    1996/71
    Canonical Title
    Unknown
    Carrier Type
    16mm film
    Has Sound
    Y
    Identification Notes
    Picture: magnetic (data migration 25/06/2021)
    Identifier
    Modification Date
    25/06/2021
    Parts
    Reference
    566670
    Sound
    sound
  • Activities
    Barcode
    INV??4586
    Canonical Identifier
    1996/71
    Canonical Title
    Unknown
    Carrier Type
    16mm film
    Has Sound
    Y
    Identification Notes
    Picture: optical (data migration 25/06/2021)
    Identifier
    Image Polarity
    negative
    Modification Date
    25/06/2021
    Parts
    Reference
    566669
    Sound
    sound
  • Activities
    Barcode
    INV222439
    Canonical Identifier
    1996/71
    Canonical Title
    Unknown
    Carrier Type
    16mm film
    Colour Type
    colour
    Has Sound
    Y
    Identification Notes
    Picture: combined (data migration 25/06/2021)
    Identifier
    Image Polarity
    positive
    Modification Date
    25/06/2021
    Parts
    Reference
    566668
    Sound
    sound
  • Barcode
    INV??3451
    Canonical Identifier
    A-3416
    Canonical Title
    Unknown
    Carrier Type
    16mm film
    Colour Type
    colour
    Identifier
    Image Polarity
    pos
    Modification Date
    25/06/2021
    Parts
    Reference
    565493

Copyright restrictions apply.

Please see our terms of use. Films on this website are provided for personal viewing. Should you wish to use the films in any other way please contact eafa@uea.ac.uk

terms of use

The data for this page was generated on 29/04/2024 02:17:16+00:00. Click to regenerate this page .